- 200ml/min flow rate (adjustable from 50 to 300 ml/min)
- Dual pumps with automatic failsafe switchover
- Automated or manual leak tests
- Alarm annunciation for flow errors
- Flow and Vacuum indications
- High reliability
- 200ml/min flow rate (adjustable from 50 to 300 ml/min)
- Dual pumps with automatic failsafe switchover
- Automated or manual leak tests
- Alarm annunciation for flow errors
- Flow and Vacuum indications
- High reliability
- 200ml/min flow rate (adjustable from 50 to 300 ml/min)
- Independent sampling trains for Total Carbon and CO2
- Dual pumps with automatic failsafe switchover
- Automated or manual leak tests
- Alarm annunciation for flow errors
- Flow and Vacuum indications
- Variable flow rates 40 to 120 L/min
- Uses standard 2” filters and cartridges
- Dual High reliability speed controlled vane pumps
- Alarm annunciation for flow errors
- Hot wire anemometer type mass flow sensor with closed loop pump control
- Optional electronics package for real time monitoring of discharges
- Open frame design to allow all service from front of unit
- Variable flow rates 20 to 100 L/min
- Uses standard 2” filters and cartridges
- Dual High reliability speed controlled vane pumps
- Alarm annunciation for flow errors
- Hot wire anemometer type mass flow sensor with closed loop pump control
- Optional electronics package for real time monitoring of discharges
- High reliability and availability
- Variable flow rates 20 to 100 L/min
- Uses standard 2” filters and cartridges
- Redundant high reliability speed controlled sampling pumps
- Redundant mass flow meters
- Automatic pump switchover
- Vacuum and flow rate displays
- Stack flow display with fixed and proportional sampling rates
- Leak test functions
- Real time analysis of emissions with data archiving
- High reliability and availability
- Variable flow rates 20 to 100 L/min
- Automated drift correction & verification of detector function
- Uses standard 2” filters and cartridges
- Redundant high reliability speed controlled sampling pumps
- Stack flow display with fixed and proportional sampling rates
- Redundant mass flow meters
- Automatic pump switchover
- Vacuum and flow rate displays
- Leak test functions
- Alarm annunciation for flow errors
- Flow and time totalizer display
- Averaging system for up to three flow meters
- 4-20mA output for flow and temperature
- Rejection of out of specification flow meter signals
- Alarm indication for failed flow meters
- Remote diagnostics of flow meters
- Single point shrouded representative sampling nozzle
- 57 LPM 2 CFM @ 1 to 12 m/s
- Single point shrouded representative sampling nozzle
- 57 LPM 2 CFM @ 1 to 24 m/s
- Single point shrouded representative sampling nozzle
- 113 LPM 4 CFM @ 4.7 to 22.7 m/s
- Single point shrouded representative sampling nozzle
- 113 LPM 4 CFM @ 21.7 to 29.7 m/s
- Single point shrouded representative sampling nozzle
- 170 LPM 6 CFM @ 2 to 20 m/s
- Single point shrouded representative sampling nozzle
- 28 LPM 2 CFM @ 0.5 to 13 m/s
- Cryogenic condenser for collection of D2O or condensible fluid samples for lab analysis
- Uses safe silicone based chiller bath and quick change condenser
- Maintains condenser below -50C dewpoint
- Dew point monitor and alarm
- Calibrated sample rate using proven dual pump design with automatic fail over
- Flow sensor, dew point monitor , pump fail over alarm
- Internally configurable span and alarm options
- Alarm contact and local visible alarm outputs for fault conditions
- Simple front panel control and alarm settings
- Floor, Wall or mobile cart mounting options
- DSP based ion chambers provide sub femtoampere sensitivity and stability with stable tritium readings lower than 1 uCi/M3
- 10 port, fast sample time (typically less then 2 minutes/port)
- configurable pre sample fast scanning mode
- Minimal line draw delays via variable speed high capacity pump system
- Dual pumps with automatic fail-safe switch over
- Automatic dryer and decontamination options
- Auto clean sample line scrubber
- Modular design with many upgrade options
- Proven reliability for all subsystems
- Single seismically qualified cabinet design
- Wireless or Coax or 1,2 or 4 pair cable installations allows simple networking
- 9 decades of measurement range
- Up to 100 M sample line draw through 1/4” to 1” lines
- web page and/or central computer interface
- Scalable design with future upgrade potential
- Local grab sample provision for lab sample analysis
- Floor, Wall or mobile cart mounting options
- Option for multiple ion chambers
-Central computer software with graphical mapping and real time time display/storage
- DSP based ion chambers provide sub femtoamp sensistivity and stability with stable tritium readings lower than 1 uCi/M3
- Dual pumps with automatic fail-safe switch over
- Automatic dryer and decontamination options
- Modular design with many upgrade options
- Proven reliability for all subsystems
- Single seismically qualified cabinet design
- 4-20 ma current loop output
- Internally configurable span and alarm options
- Alarm contact outputs for level and fault conditions
- 9 decades of measurement range
- Simple front panel control and alarm settings
- Floor, Wall or mobile cart mounting options
- Option for multiple ion chambers
- Unprecedented fast response provided by AI based Multi dimension Stochastic filter algorithm
Full function real-time Alpha-iodine-noble gas stack sampler with the high-reliability pumping system.
-ideal for both new and retrofit installations
-failsafe P&I sampling with Integrated self test and energy calibration
-multi-year release storage database
-fully qualified software with significant multi-unit operational experience